== Abridged Version ==
== Abridged Version ==


The LiCl condensation hygrometer (also called a DEWCON-sensor?? Habe ich nicht gefunden) is an electrolytic conductivity sensor.  
The LiCl condensation hygrometer '''(also called a DEWCON-sensor?? Habe ich nicht gefunden)''' is an electrolytic conductivity sensor.  
<!--[[Datei:Schematischer Aufbau eines LiCL-Messelements.JPG|thumb|left|300px|'''Abbildung 1''' - Schematischer Aufbau eines LiCl-Messelementes [Weber:1995]]]-->
[[Datei:Schematischer Aufbau eines LiCL-Messelements.JPG|thumb|left|300px|'''Abbildung 1''' - Schematischer Aufbau eines LiCl-Messelementes [Weber:1995]]]


The principle of operation is that the LiCl-salt containing ceramic sensor, which has been equipped with a heating meander and Pt 500 measuring resistor, heats up until it reaches the [[equilibrium moisture level/deliquescence humidity|Deliquescence humidity]] of the salt. At this point, no more electric current flows and the heating stops, resulting in a temperature drop. Now the sensor picks up moisture again and starts re-heating. After a while and at a specific temperature, the sensor adjusts to equilibrium. The temperature depends exclusively on the water vapor partial pressure of the ambient air. Automatically, and free of hysteresis, the water vapor pressure of the ambient air that is to be measured, is kept in equilibrium and the sensor temperature is a physically clear measure of the dew-point, similar to the automatic dew-point hygrometer.  
The principle of operation is that the LiCl-salt containing ceramic sensor, which has been equipped with a heating meander and Pt 500 measuring resistor, heats up until it reaches the [[Deliquescence humidity|equilibrium moisture level/deliquescence humidity]] of the salt. At this point, no more electric current flows and the heating stops, resulting in a temperature drop. Now the sensor picks up moisture again and starts re-heating. After a while and at a specific temperature, the sensor adjusts to equilibrium. The temperature depends exclusively on the water vapor partial pressure of the ambient air. Automatically, and free of hysteresis, the water vapor pressure of the ambient air that is to be measured, is kept in equilibrium and the sensor temperature is a physically clear measure of the dew-point, similar to the automatic dew-point hygrometer.  




Line 21: Line 24:
<math>LiCl \cdot H_2O \rightarrow LiCl (100 ^\circ C)</math>
<math>LiCl \cdot H_2O \rightarrow LiCl (100 ^\circ C)</math>


The sensor is to be protected from liquid water. Contamination of the salt may lead to drifts. (Ist mir nicht ganz klar wie das gemeint ist – z.B. Salt contamination of the sensor /LiCl salt/liquid water?)
The sensor is to be protected from liquid water. Contamination of the salt may lead to drifts. '''(Ist mir nicht ganz klar wie das gemeint ist – z.B. Salt contamination of the sensor /LiCl salt/liquid water?)
Der Fühler ist vor flüssigem Wasser zu schützen. Eine Drift kann durch Verunreinigungen des Salzes  ausgehen.
Der Fühler ist vor flüssigem Wasser zu schützen. Eine Drift kann durch Verunreinigungen des Salzes  ausgehen.'''
 
It is important to always run the LiCl covered sensor with heater voltage, because otherwise it takes up water hygroscopically and leaves the prescribed measuring position. Then, the unit is no longer operational. The lower the absolute humidity, the longer it takes for the sensor to respond to a signal.
It is important to always run the LiCl covered sensor with heater voltage, because otherwise it takes up water hygroscopically and leaves the prescribed measuring position. Then, the unit is no longer operational. The lower the absolute humidity, the longer it takes for the sensor to respond to a signal.
 
-->
[[category:Luftfeuchtemessung]][[category:Schwarz,Hans-Jürgen]][[category:R-SLaue]][[category:Review]]
[[category:Humidity Measurement]][[category:Schwarz,Hans-Jürgen]][[category:R-SLaue]][[category:inProgress]]

Revision as of 11:04, 28 October 2012

Author: Hans-Jürgen Schwarz

English Translation by Sandra Leithäuser
back to Moisture measurement methods


This article will be released soon.